ridm@nrct.go.th   ระบบคลังข้อมูลงานวิจัยไทย   รายการโปรดที่คุณเลือกไว้

Comparison of cone and cone shell configuration for depth sensitive fluorescence measurements in turbid media

หน่วยงาน Nanyang Technological University, Singapore

รายละเอียด

ชื่อเรื่อง : Comparison of cone and cone shell configuration for depth sensitive fluorescence measurements in turbid media
นักวิจัย : Ong, Yi Hong , Liu, Quan
คำค้น : DRNTU::Engineering
หน่วยงาน : Nanyang Technological University, Singapore
ผู้ร่วมงาน : Choi, Bernard , Kollias, Nikiforos , Zeng, Haishan , Kang, Hyun Wook , Wong, Brian J. F. , Ilgner, Justus F. , Tearney, Guillermo J. , Gregory, Kenton W. , Marcu, Laura , Mandelis, Andreas , Morris, Michael D.
ปีพิมพ์ : 2557
อ้างอิง : Ong, Y. H., & Liu, Q. (2014). Comparison of cone and cone shell configuration for depth sensitive fluorescence measurements in turbid media. Proc. SPIE 8926, Photonic Therapeutics and Diagnostics X, 89260J-. , http://hdl.handle.net/10220/19611 , http://dx.doi.org/10.1117/12.2038834
ที่มา : -
ความเชี่ยวชาญ : -
ความสัมพันธ์ : -
ขอบเขตของเนื้อหา : -
บทคัดย่อ/คำอธิบาย :

We have developed a novel cone shell illumination and detection configurations using combination of axicon lenses for depth sensitive fluorescence spectroscopy. The probe was demonstrated experimentally to be able to selectively detecting fluorescence from different depths from a two-layered turbid agar phantom. In addition to enhanced contrast of subsurface fluorescence measurement as compared to a conventional cone configuration implemented by a microscope objective lens, the axicon lenses based setup eliminated the need of moving the objective lens up or down to achieve depth sensitive measurements, which effectively improves the consistency of optical coupling thus would be preferred in a clinical setting.

บรรณานุกรม :
Ong, Yi Hong , Liu, Quan . (2557). Comparison of cone and cone shell configuration for depth sensitive fluorescence measurements in turbid media.
    กรุงเทพมหานคร : Nanyang Technological University, Singapore.
Ong, Yi Hong , Liu, Quan . 2557. "Comparison of cone and cone shell configuration for depth sensitive fluorescence measurements in turbid media".
    กรุงเทพมหานคร : Nanyang Technological University, Singapore.
Ong, Yi Hong , Liu, Quan . "Comparison of cone and cone shell configuration for depth sensitive fluorescence measurements in turbid media."
    กรุงเทพมหานคร : Nanyang Technological University, Singapore, 2557. Print.
Ong, Yi Hong , Liu, Quan . Comparison of cone and cone shell configuration for depth sensitive fluorescence measurements in turbid media. กรุงเทพมหานคร : Nanyang Technological University, Singapore; 2557.